Secondary Reference Temperature Standards

Model #5618 / 5627A

Small diameter sheath, 3.2mm (0.125 in) (5618)
Excellent stability
Includes ITS-90 coefficients
Vibration and shock resistant
3/4-inch bend radius for increased durability
NVLAP-accredited calibration included

From: To Order

Bookmark and Share

Click and hover to zoom. Click again to view larger image.

5618 Series Probes
For secondary level performance with full ITS-90 calibration, Hart's 5618B series PRTs are an excellent choice for critical temperature measurements. Featuring a 3.2 mm diameter (1/8 in) sheath, these industrial standards probes have reduced response time without compromising precision. This small diameter 5618A probe works well in many applications where immersion depth is limited. Larger diameter probes give more measurement error in short immersion depth applications because they conduct more heat between ambient and the sensor.

With each probe you will receive a full NVLAP-accredited calibration report. On the report you'll get the test data and the ITS-90 calibration coefficients that you can easily input into your Hart thermometer. If you are using a 1521 Handheld Thermometer readout, we'll program the coefficients directly into your INFO-CON connector.

The 5618B is also a great probe to use for calibrating your Hart 9132 or 9133 infrared calibrators. In fact, these IR black body heat sources were designed to be calibrated with this type of probe. Now you can calibrate these targets in your own lab!

For use from –200 °C to 500 °C (the six-inch model goes to 300 °C), you won't find a better industrial standard in this configuration than our 5618B. We recommend using the 5618B PRTs with the 1521, 1522, 1502A, 1529, or 1560 thermometer readouts.

5627A Series Probes
When buying a PRT, performance isn't the only criterion you need to look at. The real issues are price-to-accuracy and price-to-durability ratios.

The 5627A probes have a temperature range up to 420 °C and an accuracy as good as ±0.05 °C. They come in three different lengths. (The six-inch and nine-inch model covers –200 °C to 300 °C.) Each instrument is shipped with its ITS-90 coefficients and a calibration table in 1 °C increments.

One of the best features of this sensor is that it conforms to the standard 385 curve, letting you use your DIN/IEC RTD meters fully. Why use a probe that's less accurate than your meter?

The 5627A is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. (Bend, if any, should be specified at time of order.)

Six-inch and nine-inch 5627s are calibrated at –196 °C, –38 °C, 0 °C, 200 °C, and 300 °C. For the 12-inch version, the point at 300°C is replaced with a point at 420 °C.

Each probe is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer.

This probe is an excellent value. It has the price-to-accuracy and price-to-durability ratios you should demand in every PRT you buy!

Resistance Nominal 100W at 0 °C
Temperature Coefficient 5627: 0.00385W/W/ °C nominal
5618: 0.003923W/W/ °C nominal
Temperature Range 5627: –200 °C to 420 °C (5627-6 and 5627-9 to 300 °C; transition and cable temperature: 0 °C to 150 °C)
5618: –200 °C to 500 °C
(–200 °C to 300 °C for 5618A-6-X)
Drift Rate 5627: ±0.13 °C at 0 °C after 1000 hours at 400 °C
5618: ±0.1 °C when used periodically to 500 °C
Sheath Material

316 Stainless Steel

Leads 5627: Teflon™-insulated, nickel-plated stranded copper, 22 AWG
5618: 22 AWG Teflon, 6'
Termination Specify. See Ordering Information.
Hysteresis 5618: Less than 0.01 °C at 0 °C when using –196 °C and 420 °C as the end points.
Time Constant 5627: Four seconds maximum for 63.2 %Response to step change in water moving at 3 fps.
5618: 9 seconds max for 63.2 %
Bending Radius Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Hart lab requires 20 cm [8 in] of unbent sheath to re-calibrate.)
Thermal EMF 5618: Less than 25 mV at 420 °C
Immersion 5627: At least 100 mm (4 in) recommended
Calibration 5627: Includes a NVLAP-accredited calibration and table with R vs. T values in 1 °C increments from –196 °C to 500 °C (to 300 °C for 5627-6 and 5627-9). ITS-90 coefficients included. Optional accredited calibration available from Hart.
5618: Includes NVLAP-accredited calibration w/ITS-90 coefficients, R vs. T values in 1 °C increments
Size 5627: 5627A-12:12 in L x 1/4 in Dia.
5627A-9: 9 in L x 3/16 in Dia.
5627A-6: 6 in L x 3/16 in Dia.
5618B-12: 305 mm L x 3.2 mm dia. (12 x 1/8 in)
5618B-9: 229 mm L x 3.2 mm dia. (9 x 1/8 in)
5618B-6: 152 mm L x 3.2 mm dia. (6 x 1/8 in)
Probe Accuracy 5627: ±0.050 °C at –196 °C
±0.050 °C at 0 °C
±0.051 °C at 200 °C
±0.055 °C at 420 °C
5618: ±0.05 °C over entire range

To Order:

Hart Scientific 5618 Series Secondary PRT Temperature Sensors
5618B-6-X  152 mm (6 in) Small Diameter Probe 
5618B-9-X  229 mm (9 in) Small Diameter Probe 
5618B-12-X  305 mm (12 in) Small Diameter Probe 
2601  Probe Carrying Case   
Hart Scientific 5627A Series Secondary PRT Temperature Sensors
5627A-6-X  Secondary PRT, 152 mm x 4.7 mm (6 x 3/16 in), –200 °C to 300 °C 
5627A-9-X  Secondary PRT, 229 mm x 4.7 mm (9 x 3/16 in), –200 °C to 300 °C 
5627A-12-X  Secondary PRT, 305 mm x 6.35 mm (12 x 1/4 in), –200 °C to 420 °C 
2601  Probe Carrying Case   
X = termination. Specify "L" (mini spade lugs), "D" (5-pin DIN for Tweener Thermometers), "P" (Smart Lemo), or "S" (spade lugs).