| Calibration Gear | |||||||
![]() |
MicroCal 2KModel: 271-200/201/202
|
Range: K: -328 to 2501°F (-200 to 1372°C) Resolution: 0.1° ![]() ![]() ![]() ![]() ![]() |
Was $349 |
||||
![]() |
VA710 Thermocouple SimulatorModel: VA710
|
Range: -10 to 75mV Resolution: 0.01mV or 0.1° max ![]() ![]() ![]() ![]() ![]() |
|
||||
![]() |
VA720 RTD SimulatorModel: VA720
|
Range: 0.00 to 3200 ohm Resolution: 0.01 ohm ot 0.1°C max ![]() ![]() ![]() ![]() ![]() |
|
||||
![]() |
PIE-520Model: PIE-520
|
Range: -148°F to full scale for each of the thermocouple types Accuracy: ±0.45°F (±0.25°C) ![]() ![]() ![]() ![]() ![]() |
From |
||||
![]() |
PIE-521Model: PIE-521
|
Range: -148°F to full scale for each of the thermocouple types Accuracy: ±0.45°F (±0.25°C) ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
Martel M2000 Bench Voltage/Current CalibratorModel: Martel M2000A
|
Range: [range here] Accuracy: 0.003% of reading ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
Martel 3001 Precision CalibratorModel: Martel 3001
|
Range: [range here] Best Accuracy: 0.0025% of reading ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
USB Reference ThermometerModel: USB-REF
|
Range: -55 to 150°C / -67 to 302°F Accuracy: ±0.09°F (±0.05°C) ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
Reference ThermometerModel: 222-555
|
Range: -328 to 391°F (-199.9 to 199.9°C) Best Accuracy: ±0.1°F (±0.05°C) ![]() ![]() ![]() |
|
||||
![]() |
PDA Reference Thermometer & HACCP Recording SystemModel: 294-XXX
|
Accuracy: -58 to 302°F (-50 to 150°C): ±0.09°F (±0.05°C) ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
P700 Series & P795 Precision Handheld Reference ThermometerModel: P750/P755/P795
|
Accuracy: ±0.015°C System Accuracy ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Hart Scientific
|
Accuracy: up to ±0.002 °C with thermistors and ± 0.015°C with PRTs ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Hart Scientific
|
Accuracy: up to ±0.004°C for PRTs ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Hart Scientific 1620 "The DewK" Thermo-HygrometerModel: 1620A-S/1621A-S
|
Accuracy:±0.45°F from 59 to 95 °F / ±1.0%RH for ±5% changes within 20 to 70%RH ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Infrared Comparator CupModel: 814-132
|
Range: [range here] Resolution: [accuracy here] ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
Hart Scientific
|
Range: 50°C, 100°C, 150°C (122°F, 212°F, 302°F) Accuracy: ±1°C ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
IR-500 Portable Infrared CalibratorModel: IR-500
|
Range: 122 to 932°F (50 to 500°C) Accuracy: ±1.0°F at 212°F (±0.5°C at 100°C) ![]() ![]() ![]() ![]() ![]() |
Was $1,185 | ||||
![]() |
4180 Series
|
Range: 4180: -15 to 120ºC ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Secondary Thermistors
|
Accuracy: ±0.01°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Secondary Reference Industrial PRT's
|
Accuracy: up to ±0.050°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Secondary Reference PRT's
|
Accuracy: up to ±0.010°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Hi-Temp Secondary PRT's
|
Accuracy: up to ±0.004°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Mini Calibration BathModel: 822-950
|
Range: 32° (71°F below ambient) and 56°C (130°F) Accuracy: ±0.5°C ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
Hart Scientific
|
Resolution: 0.01° ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
Hart Scientific
|
Accuracy: better than ±0.008°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Calibration Bath FluidsModel: Varies
|
Range: -75 to 300°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
3000 Series
|
Range: 33 to 300°C Resolution: 0.1° ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
3004
|
Accuracy: ±0.5°C (+33 to +199°C) ![]() ![]() ![]() ![]() ![]() |
| ||||
![]() |
3101
|
Range: 14°F to 230°F (-10°C to 110°C) Resolution: 0.1° ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Hart Scientific
|
Accuracy: Cold block: ±0.2°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Hart Scientific
|
Accuracy: ±0.25°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
9140 Series
|
Range: 9142: -25 to 150ºC ![]() ![]() ![]() ![]() ![]() |
From | ||||
![]() |
Hart Scientific
|
Range: 150°C to 1200°C (302°F to 2192°F) Stability: ±0.5°C ![]() ![]() ![]() ![]() ![]() |
From | ||||
| Icon Legend | |
![]() |
Category Icon 1 |
![]() |
Category Icon 2 |
![]() |
Category Icon 3 |
![]() |
Category Icon 4 |
![]() |
Category Icon 5 |
![]() |
Category Icon 6 |








































