Martel M2000 Lab Calibrator

Model #Martel M2000A

Superior calibration accuracy
Direct keyboard entry or cursor entry with decade control
Automatic standby function protects device under test
Nine (9) manual/automatic setpoints per output range
Tellurium-Copper binding posts reduce thermal EMFs to <1µV
Local or RS232 remote control
Optional IEEE-488 control available
Compatible with Fluke Met/Cal® software
Optional rack/panel mount kit available

Bookmark and Share

Click and hover to zoom. Click again to view larger image.

The Martel M2000 Bench Calibrator sets a new standard in lab calibrator value — the M2000 features the accuracy and stability of calibration sources costing twice as much — and provides useful features no other calibrator offers in its class! Despite its world-class performance and powerful operating features, the M2000 Calibrator is very simple to setup and use.

Simple Data Entry
The M2000 provides simple, front-panel entry of output voltage or current using either direct keyboard entry or cursor entry.

The M2000 calibrator has an automatic OPERATE/STANDBY function, which not only protects the device under test and the M2000 from overload conditions, but also provides UL/CSA-certified safe operation when ranging to output voltages over 30V.

A second function key provides easy access for up to nine setpoints for each output range that can be recalled individually at the touch of a button, or can be stepped through automatically with control of the setpoint dwell time. The M2000 five way copper alloy binding posts provide a wide range of connection options.

Remote Control
All of the M2000 operating functions can be accessed via RS232, using a standard PC running Fluke Met/Cal® software, HyperTerminal under Windows, Visual Basic, or any other software using an ASCII interface. An IEEE-488 bus interface is available as an option.

Rock-Solid Stability
The M2000 stability and accuracy is traceable to NIST standards. The accuracy of the M2000 is specified for both 90-day and one-year intervals. A self-calibration may be performed at any time via the front panel or the remote interface.

Output Voltage

Range 0 to 100.000 mV
0 to 1.00000 V
0 to 10.0000 V
0 to 100.000 V
Resolution 0 to 100 mV Range: 1 µV
0 to 1 V Range: 10 µV
0 to 10 V Range: 100 µV
0 to 100 V Range: 1 mV
Accuracy (% of reading) 0 to 100 V Range: ±0.003% (30ppm) ±3.0 µV
0 to 1 V Range: ±0.003% (30ppm) ±20.0 µV
0 to 10 V Range: ±0.003% (30ppm) ±200.0 µV
0 to 100 V Range: ±0.003% (30ppm) ±2.0 mV
Maximum Burden (~ 1 Ohm output impedance) 0 to 100 mV Range: 10 mA
0 to 1 V Range: 10 mA
0 to 10 V Range: 10 mA
0 to 100 V Range: 1 mA

Output Current

Range 0 to 100.000 mA
Resolution 1 µA
Accuracy (% of reading) ±0.01% ±1 Count
Maximum Burden 10 V

Stability

Warm-up Time 30 minutes to rated accuracy

Temp Co.

(<18°C/>28°C) 10% of accuracy spec/°C

Environmental

Operating Temperature 0°C to +50°C
Storage Temperature -20°C to +70°C
Power Requirements: Voltage Range 90 to 240 VAC <15 VA
Dimensions 5" x 19" x 11" (17.7 x 48.26 x 27.96cm)
Weight Approx 5 lbs. (2.27 kg)
Display 16 by 2 Large character alphanumeric backlit LCDs

 