1620 "The DewK"
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Environmental Range | -32 to 122 F / 0 to 50°C ; 0 to 100% RH |
| Calibrated Temperature Accuracy ("S" Model) | ±0.45°F from 59 to 95 °F / ±0.25 °C from 15 to 35°C |
| Calibrated RH Accuracy ("S" Model) | ±2%RH from 20 to 70%RH |
| Expected Extrapolated Performance (Uncertified) | ±0.9°F / ±0.5°C outside calibrated range ±3%RH outside calibrated range |
| Delta Temperature Accuracy | ±0.045°F for ±1° changes within 59 to 95°F / ±0.025°C for ±1° changes within 15 to 35°C |
| Delta Humidity Accuracy | ±1.0%RH for ±5% changes within 20 to 70%RH |
| RH Resolution | User selectable up to 0.01% on front-panel display (0.1% recorded) |
| Inputs | Up to two sensors, measure temperature and relative humidity, detachable, cable-extendable, interchangeable, self-contained calibrations, may be assigned unique 16-character identifications |
| Display | 240 x 128 graphics monochrome LCD, displays password-protected temperature/humidity data graphically, numerically, and statistically (one or both channels); 16 pre-defined, user-changeable screen setups |
| Memory | 400,000 typical individual date/time-stamped readings |
| Alarms | Password-protected visual, audible, and external alarms for temperature, temperature rate, RH, RH rate, and fault conditions |
| Alarm Port Output | 2.5 mm two-conductor subminiature plug, 0 V normal, 11 to 12 V active, sources up to 20 mA |
| Connectivity | Ethernet, RS-232, RF (optional) |
| Ethernet | RJ45 jack, 10 Base-T or 100 Base-TX; static or dynamic (DHCP client) IP address assignment |
| Certificate | Includes Certificate of Conformance |
| Web Page | Embedded web page interface features: instrument identification, measurements, password-protected terminal page; can be disabled |
| Wireless Option | Requires wireless modem. 802.15.4 (underlies Zigbee), 2.4 GHz frequency, 1 mW transmit power, 30 m (100 ft) typical unobstructed range; can be disabled |
| Mounting | Wall mounted (hardware included) or set on a bench top |
| Power | 12 V dc from external 100 to 240 V dc power supply |
| Battery Backup | Standard 9 V battery enables continued measuring during power disruptions |
| Size (DewK) (HxWxD) | 4.9 x 8.3 x 2.0 in / 125 x 211 x 51 mm |
| Size (Sensors) (LxDia) | 3.1 x 0.75 in / 79 x 19 mm |
| Weight | 1.5 lb / 0.7 kg |
| Calibration | Certificate of NIST-traceable NVLAP accredited temperature and humidity calibration included; As Found and As Left data supplied at three temperature points and three humidity points each at 20 °C (68 °F); Complies with NCSL/ISO/IEC 17025:2000 and ANSI/NCSL Z540-1-1994 |
| LogWare III (Optional Software) |
Requirements include: Microsoft® Windows® 2000 (SP4) or XP (SP2) operating system, IBM compatible Intel Pentium® IV 1 GHz PC processor or better, 512 Mb RAM (1Gb or more recommended), 200 Mb HDD space for installation (additional free space recommended for data storage), CD-ROM drive for installation |
Graphical & Statistical Data
The DewK lets you view data just about any way you like it. Both graphical data and statistical data can be shown for temperature and humidity from one or two inputs. Modifying any of the standard screens is easily done, so you see exactly what you want—no more, no less.
LogWare III Software
If you really want to get the most out of your DewK, LogWare III is an investment worth every penny. As client-server or stand-alone software, it remotely monitors and logs an unlimited number of concurrent log sessions into a single database. That means data from many DewKs can be managed in real time via Ethernet, RS-232, or wireless connections.
Temperature Log BookModel: TLOG1
|
Quick and easy way to keep temperature records. Records date, time, item or location, temperature, comments or actions, and initials. Tips and reference temperatures are provided as well as simple instructions to check a thermometer's calibration. | ||
NIST-Traceable RH CalibrationModel: CAL-RH1PT
|
1-point RH calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes calibration report and actual test data. |
|
|
NIST-Traceable RH CalibrationModel: CAL-RH2PT
|
2-point humidity calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes calibration report and actual test data. |
|
|
NIST-Traceable RH CalibrationModel: CAL-RH3PT
|
3-point humidity calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes single temperature at ambient, calibration report and actual test data. |
|
|
| To Order | |||
| 1620A-S | The DewK Thermo-Hygrometer, includes one standard-accuracy sensor, wall bracket, and RS-232 cable. | ||
| 1621A-S | The DewK Thermo-Hygrometer Kit, includes two standard-accuracy sensors, wall bracket, RS-232 cable, 25 ft sensor extension cable, sensor wall bracket, sensor case, and 9936A LogWare III software single-PC licence. | ||
| 2626-S | Spare Sensor, standard accuracy | ||
| 2627-S | Spare Sensor Kit, (includes high-accuracy sensor, sensor case, sensor wall mount bracket, and 25 ft / 7.6m extension cable) | ||
| 2628 | Cable, Sensor Extension, 25ft / 7.6m | ||
| 2629 | Cable, Sensor Extension, 50ft / 15.2m | ||
| 9936A | LogWare III Software(single license) | ||