T and D RTR 500 Series Wireless LAN or GSM (Cellular) Loggers
Model #RTR-501 / 502 / 503
Transmits data to LAN or over cellular network
Water/splash resistant
Single Channel (RTR-501: internal)
Single Channel (RTR-502: external)
Dual Channel (RTR-503: temp/humid)
Dual Channel (RTR-505-TC: external Thermocouple)
Single Channel (RTR-505-Pt: external RTD)
Stores 16,000 readings
LCD temperature display
Optional 4 year battery life or AC adapter
Optional network hub with built-in email server
 Click and hover to zoom. Click again to view larger image.
Transmit temperature and humidity data anywhere over cellular network or any wired or wireless LAN with a Series 500 data logger. Store readings automatically to your FTP site for monitoring real-time readings from anywhere in the world.
Logger Models
With 5 models to choose from, our new Series 500 data loggers can record ambient temperatures in freezers down to -76°F, and high temperature applications to 3,000°F using optional probes. Select a model that uses external Thermistors, 3- or 4-wire RTDs, or Thermocouples to monitor and record temperatures of cold rooms, ovens, pharmaceuticals, medical devices, lab equipment and more.
Data Collectors
Choose from 4 optional data collection devices to transmit and store recorded data. For monitoring one location, readings can be collected directly to a LAN via USB to a central PC, or through a wired or wireless hub. For remote monitoring, a cellular network hub can be used with a cellular SIM card to transmit data through an existing cellular network. Once data is collected and stored to the user-selected location, readings can be accessed by all internal or external parties. An optional handheld unit can be used to collect data wirelessly up to 500 feet (150m) and then downloaded to a central PC for storage.
Each 500 Series logger includes customizable alarms that send email or text message alerts when alarm conditions are met. Also included is free data analytic software for charting trends, printing graphs, exporting to Excel, and viewing history data. Each logger can record up to 16,000 readings with temperature accuracy to ±0.3°C.
Eliminate paper logs and mounds of filing with a Series 500 logger and securely store your valuable temperature and humidity data from anywhere for quick, easy viewing at your desktop PC.
 |
RTR-501
Water Resistant Wireless Logger
Model: RTR-501
- Single channel internal
- IP67 Water resistant
- Wireless up to 500 feet (150 meters)
- LCD temperature display
|
Range: -40 to 176°F
(-40 to 80°C)
Accuracy: ±0.9°F (±0.5°C) |
|
|
 |
RTR-502
Water Resistant Wireless Logger with External Probe
Model: RTR-502
- Single channel external
- IP-64 splash resistant
- Wireless up to 500 feet (150 meters)
- LCD temperature display
|
Range: -76 to 311°F
(-60 to 155°C)
Accuracy: ±0.5°F (±0.3°C) from 4 to 176°F (-20 to 80°C)
|
|
|
 |
RTR-503
Water Resistant Wireless Temp & Humidity Logger
Model: RTR-503
- Dual channel external
- Wireless up to 500 feet (150 meters)
- LCD temperature display
- Splash resistant
|
Range: -32 to 131°F
(0 to 55°C)
10 to 95% RH
Accuracy: ±0.5°F (±0.3°C)
±5% RH (at 25°C and 50% RH)
|
|
|
 |
RTR-505-Pt
Water Resistant Wireless
High Temperature Logger.
Accepts 3/4-Wire PT100/PT1000 RTD Probes
Model: RTR-505-Pt
- Single channel external
- Splash resistant
- Wireless up to 500 feet (150 meters)
- Uses 3/4 wire PT100/PT1000 RTD platinum probes
|
Range: -326 to 1112°F
(-199 to 600°C)
Accuracy: to ±0.3°C
(3% of reading)
|
|
|
 |
RTR-505-TC
Water Resistant Wireless
High Temperature Logger.
Model: RTR-505-TC
- Single channel external
- Splash proof
- Wireless up to 500 feet (150 meters)
- Reads type K, J, T, S thermocouples
|
Range: -326 to 3092°F
(-199 to 1700°C)
Accuracy: to ±0.3°C
(3% of reading)
|
|
|
|
 |
Wireless USB
Data Collector & Repeater
Model: RTR-500
- Battery powered, daisy-chained built-in repeater
- Real-time monitoring & scheduled downloads
- Connectcs via USB to PC
- Send email alerts
Download datasheet |
USB based data collection with built-in daisy chain repeater for all RTR-500 Series loggers for expanded range. Download data on demand or on schedule with real-time monitoring with PC based utility software. Battery powered for convenience in repeating signal in difficult places. Built-in alarm notification via email or text messaging.
|
|
|
 |
Wireless or Wired
Network Hub
Model: RTR-500NW / RTR-500AW
- GSM Cellular phone ready
- Web application displays current readings
- Email/text alert messages
- Battery or AC powered
Download datasheet |
Log temperature and humidity data from anywhere. Great for trucks, boats, and remote locations. Data transmitted via cellular network to any FTP site or hosted web location. Automatic downloads and real time monitoring keeps data easily accessible. Requires SIM card from cellular carrier. Battery or AC powered.
|
From:
|
|
 |
Cellular Network GSM Base Station
Model: RTR-500GSM
- GSM Cellular phone ready
- Web application displays current readings
- Email/text alert messages
- Battery or AC powered
Download datasheet |
Log temperature and humidity data from anywhere. Great for trucks, boats, and remote locations. Data transmitted via cellular network to any FTP site or hosted web location. Automatic downloads and real time monitoring keeps data easily accessible. Requires SIM card from cellular carrier. Battery or AC powered.
|
|
|
 |
Wireless Handheld
Data Collector
Model: RTR-500DC
- Range up to 500' (150M)
- Stores up to 250 settings
- Manages up to 32 loggers in up to 7 groups
- Monitors real-time data
Download datasheet |
Collect data from all registered RTR-500 Series loggers directly to the RTR-500DC Handheld for later downloading to PC. Eliminates need for removing loggers from installation. Stores up to 260,000 readings from up to 250 download sessions. Controls start/stop, logging interval, as well as other logging functions in the field. Graphical display shows trend data. Monitor current readings from any logger in real-time. Includes backlit display for poorly lit areas.
|
|
|
| RTR-501 |
|
| Measurement Channel |
1 Temperature Channel |
| Internal Temp Sensor |
-40 to 80°C |
| External Temp Sensor |
- |
| External Humidity Sensor |
- |
| Measurement Accuracy |
±0.5°C |
| Measurement Display Resolution |
0.1°C |
| Sensor |
Thermistor |
| Recording Interval |
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes (15 variations) |
| Recording Capacity |
16,000 Readings x 1 Channel |
| Measurement method |
Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full) |
| LCD display |
Current Readings, Recording Settings, Battery Life Warning, Over Measurement Range Warning, Unit of Measurement |
| Battery |
Lithium battery (LS14250(SAFT) x 1 or AC Adapter |
| Battery Life |
Approximately 6 months (depends on environment, interval and battery performance) |
| Wireless |
FCC Part 15 section 249 / IC RSS-210 up to 100m (varies with conditions) |
| Interface |
Wireless & Optical Communication |
| Communication Speed |
Wireless- Approx 2,000 readings/minute Optical- Approx 6,000 readings/minute |
| Water Resistance Capacity * |
IP67 |
| Dimensions |
H62mm x W47mm x D19mm (excluding protusions / antenna length 20mm) D50mm with RTR-05B1 |
| Weight |
56g (Including battery) 109g with RTR-05B1 |
| Temperature Resistance of Unit |
-40 to 80°C |
| Standard Sensor |
Built-in |
| Software |
Compatible with Microsoft Windows Vista English
For software description and specifications, see Datasheet |
| |
RTR-502 |
RTR-505Pt |
| Measurement Channel |
1 Temperature Channel |
1 Temperature Channel |
| Internal Temp Sensor |
- |
| External Temp Sensor |
-60 to 155°C |
-199.9 to 650°C |
| External Humidity Sensor |
- |
| Measurement Accuracy |
Average ±0.3°C (-20 to 80°C)
Average ±0.5°C
(-40 to -20°C / 80 to 110°C)
Average ±1.0°C
(-60 to -40°C / 110 to 155°C) |
±0.5°C + 0.3% of reading |
| Measurement Display Resolution |
0.1°C |
| Sensor |
Thermistor |
Pt100, Pt1000 |
| Recording Interval |
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes (15 variations) |
| Recording Capacity |
16,000 Readings x 1 Channel |
| Measurement method |
Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full) |
| LCD display |
Current Readings, Recording Settings, Battery Life Warning, Over Measurement Range Warning, Unit of Measurement |
| Battery |
Lithium battery (LS14250(SAFT) x 1 or AC Adapter |
| Battery Life |
Approximately 6 months (depends on environment, interval and battery performance) |
| Wireless |
FCC Part 15 section 249 / IC RSS-210 up to 100m (varies with conditions) |
| Interface |
Wireless & Optical Communication |
| Communication Speed |
Wireless- Approx 2,000 readings/minute Optical- Approx 6,000 readings/minute |
| Water Resistance Capacity * |
IP64 ** |
| Dimensions |
H62mm x W47mm x D19mm (excluding protusions / antenna length 20mm) D50mm with RTR-05B1 |
| Weight |
56g (Including battery) 109g with RTR-05B1 |
| Temperature Resistance of Unit |
-40 to 80°C |
| Standard Sensor |
TR-5106 |
RTR-05P |
| Software |
Compatible with Microsoft Windows Vista English
For software description and specifications, see Datasheet |
Compatible with Microsoft Windows Vista English
For software description and specifications, see Datasheet |
| RTR-503 |
|
| Measurement Channel |
1 Temp and 1 Humidity Channel |
| Internal Temp Sensor |
- |
| External Temp Sensor |
0 to 55°C |
| External Humidity Sensor |
10 to 95%RH |
| Measurement Accuracy |
Average ±0.3°C (-20 to 80°C) ±5%RH (at 25°C and 50%RH) |
| Measurement Display Resolution |
0.1°C, 1%RH |
| Sensor |
- |
| Recording Interval |
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes (15 variations) |
| Recording Capacity |
8,000 Readings x 2 Channels |
| Measurement method |
Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full) |
| LCD display |
Current Readings, Recording Settings, Battery Life Warning, Over Measurement Range Warning, Unit of Measurement |
| Battery |
Lithium battery (LS14250(SAFT) x 1 or AC Adapter |
| Battery Life |
Approximately 6 months (depends on environment, interval and battery performance) |
| Wireless |
FCC Part 15 section 249 / IC RSS-210 up to 100m (varies with conditions) |
| Interface |
Wireless & Optical Communication |
| Communication Speed |
Wireless- Approx 2,000 readings/minute Optical- Approx 6,000 readings/minute |
| Water Resistance Capacity * |
IP64 ** |
| Dimensions |
H62mm x W47mm x D19mm (excluding protusions / antenna length 20mm) D50mm with RTR-05B1 |
| Weight |
56g (Including battery) 109g with RTR-05B1 |
| Temperature Resistance of Unit |
-40 to 80°C |
| Standard Sensor |
TR-3310 |
| Software |
Compatible with Microsoft Windows Vista English
For software description and specifications, see Datasheet |
| RTR-505TC |
|
| Measurement Channel |
1 Temperature |
| External Temp Sensor |
Type K: -199 to 1300°C
Type J: -199 to 750°C
Type T: -199 to 400°C
Type S: -20 to 1700 °C
|
| Measurement Accuracy |
Type K, J, T: ±0.3°C + 0.3% of reading
Type S: ±1°C + 0.3% of reading |
| Measurement Display Resolution |
0.1°C |
| Sensor |
Thermocouple |
| Recording Interval |
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes (15 variations) |
| Recording Capacity |
16,000 |
| Measurement method |
Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full) |
| LCD display |
Current Readings, Recording Settings, Battery Life Warning, Over Measurement Range Warning, Unit of Measurement |
| Battery |
Lithium battery (LS14250(SAFT) x 1 or AC Adapter |
| Battery Life |
Approximately 6 months (depends on environment, interval and battery performance) |
| Wireless |
FCC Part 15 section 249 / IC RSS-210 up to 100m (varies with conditions) |
| Interface |
Wireless & Optical Communication |
| Communication Speed |
Wireless- Approx 2,000 readings/minute Optical- Approx 6,000 readings/minute |
| Water Resistance Capacity * |
IP64 ** |
| Dimensions |
H62mm x W47mm x D19mm (excluding protusions / antenna length 20mm) D50mm with RTR-05B1 |
| Weight |
56g (Including battery) 109g with RTR-05B1 |
| Temperature Resistance of Unit |
-40 to 80°C |
| Standard Sensor |
TR-3310 |
| Software |
Compatible with Microsoft Windows Vista English
For software description and specifications, see Datasheet |
* Not for continued immersion
** The water resistance rating with the sensor or input cable connected is IP64
System Setup
USB or LAN
Select a sytem to meet your needs.
(click to enlarge)
Software
T&D Graph
- Software included in price of data collector
- Compatible with all RTR-500 Series logger, RTR-500DC Handheld
- View up to 8 channels simultaneously on graphical display
- Graphical display with channel zoom, color editing, on/off channel display
- Data display with high, low, average, time and differential between markers
- File output compatible with .csv format
- Compatible with Windows 7 32/64 bit English, Vista 32 bit, XP SP2 or above
| Optional Probes for RTR-505-TC: |
Optional Type K Thermocouple Probes
- Hundreds of probes to choose from
- Penetration, surface, high temp, wire, and more
- Select coiled or flat cables with optional extended cable lengths
 |
Select Category to View Probes |
|
Optional Type T Thermocouple Probes
- Hundreds of probes to choose from
- Penetration, surface, high temp, wire, and more
- Select coiled or flat cables with optional extended cable lengths
 |
Select Category to View Probes |
|
|
 |
ABS Bracket
Model: TR-05K3
- Convenient wall mounting bracket
- Operates in -40 to 176°F (-40 to 80°C) environment
- For use with all RTR-5 Series loggers
|
Monitor ambient conditions with optional wall bracket. Includes two screw holes for convenient attachment. For use with all RTR-5 Series loggers with standard battery. |
|
|
 |
Large Capacity Battery
Model: RTR-500B1
- Extends battery life to 2 years
- Includes high capacity Lithium battery
- Operates in -40 to 176°F (-40 to 80°C) environment
|
Extends the battery life of any RTR-500 Series logger from 6 months to 2 years. Kit includes high capacity Lithium battery, new o-ring seal, and new deeper rear housing to fit larger battery. Easy to install by removing two small screws on back housing. |
|
|
 |
AC Adapter
Model: RTR-500A1
- Connects any RTR-500 Series logger to AC power
- Includes Ni-MH battery for power loss (4 days)
- Operates in 32 to 140°F (0 to 60 °C) environment
|
Connects any RTR-5 Series logger to AC power for continuous use without worry of battery power loss. Includes NiMH backup battery for 4 days of power in event of AC power loss. Extends rear housing to fit components. Includes 110VAC power adapter, US plug. Easy to install in the field by removing two screws. |
|
|
 |
Low Temp Battery Set
Model: TR-11P2
- Lithium battery
- Insulation tube
- Maintenance kit
|
Low temperature battery kit for loggers. Includes battery, insulation tube and a maintenance kit for T&D loggers |
|
|
 |
NIST-Traceable Calibration
Model: CAL-2PT
- 2-Point calibration
- Traceable certificate
|
2-point temperature calibration performed in ThermoWorks' NIST-Traceable calibration lab. Includes calibration report and actual test data.
|
|
|
 |
NIST-Traceable RH Calibration
Model: CAL-RH2PT
- 2-Points: 30%, 60%
- Lab calibration using certified RH sources
|
2-point humidity calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes calibration report and actual test data.
|
|
|
| Optional Probes for RTR-502 / RTR-503: |
|
|
|
| Model/Description |
Range |
Price |
|
|
TR-2C30 T&D Probe Extension Cable (RTR-502 only)  |
-76 to 311°F
(-60 to 155°C) |
|
|
|
TR-5106 T&D Replacement Teflon-Shielded General Purpose Immersion Probe (RTR-502)  |
-76 to 311°F
(-60 to 155°C) |
|
|
|
TR-5220 T&D Optional Stainless Steel Sheath Immersion Probe (RTR-502)  |
-76 to 311°F
(-60 to 155°C) |
|
|
|
TR-5420 T&D Optional Stainless Steel Sheath Penetration Probe (RTR-502)  |
-76 to 311°F
(-60 to 155°C) |
|
|
|
TR-3310 T&D Optional Temp/Humidity Sensor (RTR-503)  |
32 to 131°F
(0 to 55°C)
10 to 95% RH |
|
|
|
| Optional Probes for RTR-505-Pt: |
|
|
|
| Model/Description |
Accuracy |
Price |
|
|
TR-8100-4 T&D General Purpose Probe, -50 to 200°C
 |
±0.15°C @
0°C
(±0.27°F @
32°F) <Class A> |
|
|
|
TR-8120-8 T&D High Temperature Probe, -200 to 600°C  |
±0.15°C @
0°C
(±0.27°F @
32°F) <Class A> |
|
|
|
THS-160-125 T-Handle, Heavy-Duty Penetration Probe, -30 to 200°C  |
±0.15°C @
0°C
(±0.27°F @
32°F) <Class A> |
|
|
|
|