T&D TR-700W Series Network connected Temp/Humidity Data Loggers

Model #TR-701NW/TR-701AW, TR-702NW/TR-702AW, TR-702NW-H/TR-702AW-H

Network connected - wired (-NW) or wireless (-AW)
Free web storage for data viewing & archiving
Warning alerts via email, text or external contacts Measures temperature and/or humidity
Dual channel
Holds up to 8,000 data set recordings
Temp ranges from -40 to 230°F (-40 to 111°C) or -76 to 311°F (-60 to 155°C) with optional temp sensor
Replaces TR-71W & TR-72W

From: To Order

Bookmark and Share


Click and hover to zoom. Click again to view larger image.

With built-in Ethernet or Wi-Fi, a TR-700W Series logger will measure critical temperature and humidity data in the warehouse, prep area, lab or on the factory floor and stay connected. These new TR-700W Series loggers connect into your existing LAN with a wired or wireless connection and provide real-time data viewing and archiving within your network or in the cloud.

Select a Wi-Fi unit (ends in –AW) and choose from models with two temperature inputs (TR-701), temperature and humidity (TR-702), or high accuracy temperature and humidity (TR-702-H).

If a wired connection is preferred, select an Ethernet unit (ends in –NW). The same product configuration exists with dual channel temperature, temp & humidity, and temp & humidity with high accuracy. Each logger includes an AC power adapter and internal CR-2032 coin cell battery for data backup if power is lost.

Once connected to your LAN, you can configure warning emails to your mobile devices, change settings through your browser, set auto data downloads, export for analysis, or store the data to your FTP site or to the free T&D WebStorage Service.

With data stored to the T&D WebStorage Service, you can view data in real-time, set groups and custom views, report archived data to T&D Graph software, and share with all users and devices with active browsers. You'll pay a monthly fee with most logging systems, but not with ThermoWorks. Web storage is free up to 20MB.

Looking for local alarms with blinky lights and buzzers? All TR-700W Series loggers include alarm-enabled contacts for connecting an external device when limits are exceeded. Connect an audible alarm or LED light so your staff knows when to check the conditions.

With a TR-700W Series logger everything is included in the price: software, connection cable, AC adapter, and ThermoWorks technical support!

  TR-701NW /
TR-701AW
TR-702NW /
TR-702AW
TR-702NW-H /
TR-702AW-H
Measurement Channels Temperature 2ch Temperature 1ch /
Humidity 1ch
Temperature 1ch /
Humidity 1ch
Temp Sensor (External) Thermistor Thermistor / Polymer Resistance Platinum Resistance / Electrostatic Capacitance
Measurement Range Supplied Sensor: -40 to 230°F (-40 to 110°C)
Optional Sensor: -76 to 311°F (-60 to 155°C)
32 to 131°F (0 to 55°C) / 10 to 95%RH -22 to 176°F (-30 to 80°C) / 0 to 99%RH
Measurement Accuracy ±0.5°F from -4 to 176°F (±0.3°C from -20 to 80°C)
±0.9°F from -40 to -4 /
176 to 230°F
(±0.5°C from -40 to -20 /
80 to 110°C)
±0.9°F (±0.5°C)
±5%RH at 77°F (25°C),
50%RH
±0.5°F from 32 to 122°F
(±0.3°C from 0 to 50°C)
±0.9°F (±0.5°C) thereafter
±2.5%RH at 77°F (25°C),
10 to 85%RH
±4.0%RH at 77°F (25°C),
0 to 10%RH or 85 to 99%RH
Resolution 0.1° 0.1° / 1%RH 0.1° / 0.1%RH
Recording Interval 1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes (15 variations)
Recording Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Measurement method Endless (Overwrite oldest data when capacity is full)
LCD display Measurements (alternating display), Power warning mark, etc.
Communication Interfaces TR-701NW / 702NW: Wired LAN
RJ45 Connector 100 Base-TX / 10 Base-T AutoMDI / MDI-X
TR-701AW / 702AW: Wireless LAN
Internal wireless LAN antenna IEEE 802.11b/g
WEP(64bit/128bit / WPA-TKIP/WPA2-AES
USB Communication (For Setup)
Power Includes AC Adaptor (AD-0638 or AD-0638-C) / Backup Power: Coin Type Lithium Battery (CR-2032)*
Data Backup Approx. 3 months (backup battery CR-2032 only without AC adaptor)
Dimensions 2.17 H x 3.07 W x 1.46 D inches (55 H x 78 W x 37 D mm)
Weight 0.18 lbs (82 g)
Operating Environment 14 to 140°F (-10 to 60°C)
Standard Sensor TR-0106 THA-3151 HHA-3151(High-Precision Type)
Compatible OS Desktop Browser: Internet Explorer (6.0 or later), Firefox (15.0 or later), Chrome (22.0 or later), Safari (6.0 or later)
Mobile Browser: Safari (iOS), Chrome (iOS, Android), Firefox (Android)

* The supplied lithium battery is for data backup during power failure and for emergency use only. Note that network communication cannot occur when using only the battery.

PDFDownload Quick Start Guide for TR-700W Series Loggers

PDFDownload TR-700NW/AW Configuration Guide

PDFClick to download T&D Graph (Beta) Software (v0.96.0)


T&D Webstorage Service

System Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access real-time and archived logger data from anywhere using an active web browser with our free cloud-based storage service. Data from all your loggers can be configured to transmit data automatically to the WebStorage Service. Set up custom views, download archived data to your PC for analysis, view logger readings and battery levels, display graphs and trends, and much more. The best feature is that it's free! Viewable from any computer, tablet, or Smartphone with browser access.

Click here to view the online demo.


TR-700 Series Network Configuration Diagram

Network Connection

 

 

 

 

 

 

 

 

 

 

 


T&D Graph & Data Analysis Software

Customizable Ticket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The newly designed software "T&D Graph" gives you greater management and analyzing power for dealing with the recorded data (TRZ format) collected from TR-700W Series loggers.

T&D Graph allows you to read larger numbers of recorded data files (TRZ format) into the same graph, merge data, view and save data various ways. It can be downloaded free of charge here.

This versatile graph tool not only allows the user to directly access data stored in the WebStorage Service, but the user can also specify conditions such as time period for which data to view and analyze.

It is also possible to sample and filter data, add memos and write comments directly on the graph, as well as, save data to CSV Format for use with common spreadsheet software.

Click for free download of T&D Graph (Beta) Software

 

Optional Probes      
Model/Description Temp Range Price  
Temperature (TR-701NW & TR-701AW)      
TR-0106 T&D Replacement Teflon Sheath Temperature Probe
-40 to 230°F
(-40 to 110°C)
TR-1220 T&D Optional Stainless Steel Temperature Immersion Probe
-76 to 311°F
(-60 to 155°C)
TR-0506 T&D Optional Stainless Steel Penetration Probe, 11.5"L
-40 to 230°F
(-40 to 110°C)
TR-0706 T&D Optional Stainless Steel Penetration Probe, 2"L
-40 to 230°F
(-40 to 110°C)
THA-3151 T&D Temperature/Humidity Sensor
Temperature:
32 to 131°F
0 to 55°C)

Humidity:
10 to 95%RH
HHA-3151 T&D Temperature/Humidity Sensor-High-Precision Type
Temperature:
-22 to 176 °F
-30 to 80°C)

Humidity:
0 to 99%RH
TR-1C30 T&D Extension Cable for Temperature Probes only. 10'L
 

Interface

Spare/Replacement AC Adaptor

Model: AD-0638

  • Use with T&D TR-700 Series Loggers, T&D RTR-500GMS Data Collector and TR-57DCi Data Collector
Optional spare AC Adaptor for use with TR-700 Series Loggers, RTR-500GSM Data Collector and TR-57DCi Data Collector. One is included with each TR-700 Series Logger.


Batteries

CR2032 Batteries

Model: THS-839-195

  • CR2032 batteries x 2
Package of 2 batteries. Standard CR2032 size.


Cal Cert

NIST-Traceable Temperature Calibration

Model: CAL-2PT

  • 2-Point calibration
  • Traceable certificate
2-point temperature calibration performed in ThermoWorks' NIST-Traceable calibration lab. Includes calibration report and actual test data.
(Please allow 1-2 weeks for cal lab processing)


Cal Cert

NIST-Traceable RH Calibration

Model: CAL-RH2PT

  • 2-Points: 30%, 60%
  • Lab calibration using certified RH sources
  • Single ambient temperature
2-point humidity calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes calibration report and actual test data. Includes a single temp at ambient.
(Please allow 1-2 weeks for cal lab processing)

 

ThermoWorks Image

TR-701NW
Network connected (Ethernet) Temp Data Logger

Model: TR-701NW

  • Dual Channel: Temperature - External
  • LCD temperature display
  • Ethernet LAN connection

Range: -40 to 230°F (-40 to 110°C)

Accuracy: ±0.5°F from -4 to 176°F (±0.3°C from -20 to 80°C)
±0.9°F from -40 to -4 / 176 to 230°F
(±0.5°C from -40 to -20 / 80 to 110°C)

°C/°F SwitchableMax/MinNetwork-CapableIP RatedAlarmThermistor

 


ThermoWorks Image

TR-701AW
Network connected (WIFI) Temp Data Logger

Model: TR-701AW

  • Dual Channel: Temperature - External
  • Wireless up to 500 feet (150 meters)
  • LCD temperature display
  • WIFI LAN connection

Range: -40 to 230°F (-40 to 110°C)

Accuracy: ±0.5°F from -4 to 176°F (±0.3°C from -20 to 80°C)
±0.9°F from -40 to -4 / 176 to 230°F
(±0.5°C from -40 to -20 / 80 to 110°C)

°C/°F SwitchableMax/MinNetwork-CapableWireless-ReadyIP RatedAlarmThermistor

 


ThermoWorks Image

TR-702NW
Network connected (Ethernet) Temp/Humidity Data Logger

Model: TR-702NW

  • Dual Channel: Temperature & Humidity - External
  • LCD temperature display
  • Ethernet LAN connection

Temp Range: 32 to 131°F (0 to 55°C)
Humidity Range: 10 to 95%RH

Temp Accuracy: ±0.9°F (±0.5°C)
Humidity Accuracy: ±5%RH at 77°F (25°C), 50%RH

 

°C/°F SwitchableMax/MinNetwork-CapableIP RatedAlarmThermistorMeasures Relative Humidity

 


ThermoWorks Image

TR-702AW
Network connected (WIFI) Temp/Humidity Data Logger

Model: TR-702AW

  • Dual Channel: Temperature & Humidity - External
  • Wireless up to 500 feet (150 meters)
  • LCD temperature display
  • WIFI LAN connection

Temp Range: 32 to 131°F (0 to 55°C)
Humidity Range: 10 to 95%RH

Temp Accuracy: ±0.9°F (±0.5°C)
Humidity Accuracy: ±5%RH at 77°F (25°C), 50%RH

 

°C/°F SwitchableMax/MinNetwork-CapableWireless-ReadyIP RatedAlarmThermistorMeasures Relative Humidity

 


ThermoWorks Image

TR-702NW-H
Network connected (Ethernet) High Accuracy Temp/Humidity Data Logger

Model: TR-702NW-H

  • Dual Channel: Temperature & Humidity - External
  • LCD temperature display
  • High accuracy to ±0.5°F (±0.3°C); 2.5% RH
  • Ethernet LAN connection

Temp Range: -22 to 176°F (-30 to 80°C)
Humidity Range: 0 to 99%RH

Temp Accuracy: ±0.5°F from 32 to 122°F (±0.3°C from 0 to 50°C)
±0.9°F (±0.5°C) thereafter
Humidity Accuracy: ±2.5%RH at 77°F (25°C), 10 to 85%RH
±4.0%RH at 77°F (25°C), 0 to 10%RH or 85 to 99%RH

 

°C/°F SwitchableMax/MinNetwork-CapableIP RatedAlarmMeasures Relative Humidity

 


ThermoWorks Image

TR-702AW-H
Network connected (WIFI) High Accuracy Temp/Humidity Data Logger

Model: TR-702AW-H

  • Dual Channel: Temperature & Humidity - External
  • Wireless up to 500 feet (150 meters)
  • LCD temperature display
  • High accuracy to ±0.5°F (±0.3°C); 2.5% RH
  • WIFI LAN connection

Temp Range: -22 to 176°F (-30 to 80°C)
Humidity Range: 0 to 99%RH

Temp Accuracy: ±0.5°F from 32 to 122°F (±0.3°C from 0 to 50°C)
±0.9°F (±0.5°C) thereafter
Humidity Accuracy: ±2.5%RH at 77°F (25°C), 10 to 85%RH
±4.0%RH at 77°F (25°C), 0 to 10%RH or 85 to 99%RH

 

°C/°F SwitchableMax/MinNetwork-CapableWireless-ReadyIP RatedAlarmMeasures Relative Humidity

 

 


Our Company


 

Gift Wrap

Gift Wrapping

We'll wrap your gift in our custom gift paper, trimmed with a bow and gift tag. The rich, graphite and silver combination is suitable for any occasion or anybody.

Enter a custom message for the handwritten tag (Up to 50 characters). Cost for wrapping is $4.99 per item. Each item wrapped separately. Selectable in the order info where available. Some items can not be wrapped.

Ordering more than one of the same item but don't want them all wrapped? Just add each item you want wrapped to your shopping cart individually and select the wrapping option. Add your custom greeting for each wrapped item separately as you add the item to your cart.