T and D TR-7 Series 2 Channel Loggers with USB

Model #TR-71U / TR-72-U

Measure temperature from -76°F to 311°F (-60 to 155°C)
Measure humidity from 10 to 95%
Measure barometric pressure from 750 to 1100hPa
Dual channel temperature (TR-71U)
Dual temperature/humidity (TR-72U)
Records 8,000 readings per channel
Fast download to PC via USB
Optional download to handheld device without removing from location
Start and stop recording directly from front panel

From: To Order

Bookmark and Share

Click and hover to zoom. Click again to view larger image.

For environmental recording of temperature, humidity, and barometric pressure with an easy to read digital display, our new TR-71U/72U or 73U will meet your requirements. These lightweight instruments include a multi-channel measurement with the capability to store 8,000 readings per channel on board with 15 selectable recording intervals.
For temperatures only, you'll love the TR-71U. Each unit ships with two temperature probes on 24" of cable so you can position the main unit away from your target area. With optional probes, measurements can be made in liquids, solids, vapors, and in environments down to -40°C or -40°F.

If you need to record humidity as well, the TR-72U is your instrument. An optional temperature/humidity probe is available with 40" of cable to record remotely. Temperature and humidity data are recorded and downloaded simultaneously.

For all three inputs, you'll need our TR-73U which does everything the TR-72U does with one more input for barometric pressure. This 3-channel unit records 8,000 reading on board for each input.

Each unit includes easy to use Windows software for graphical presentation of the downloaded data, statistical viewing, exporting, all with the ability to overlay up to 8 channels on one graph. Its USB connection allows for fast data downloading.

Want more? How about downloading data without removing your units from their location? Add on our RTR-57U Handheld Data Collector and with a download cable you can dump your recorded data directly to the handheld unit for later download to the PC.

We make temperature monitoring easy and accurate.

TR-71U  
Measurement Channels 2: 1 internal & 1 external or
2 external
Internal Temperature Sensor
(Thermistor)
-10 to 60°C
External Temperature Sensor
(Thermistor)
-40 to 110°C
Optional Temperature Sensor Range -60 to 155°C*
Humidity Sensor
(Macromolecular Humidity Sensor)
N/A
Barometric Pressure Sensor
N/A
Temperature Accuracy (Standard Sensors) Average ±0.3°C (-20 to 80°C); Average ±0.5°C (-40 to -20°C / 80 to 110°C)
Humidity Accuracy N/A
Barometric Pressure Accuracy N/A
Measurement Resolution Display 0.1°C
Recording Interval 1,2,5,10,15,20,30 seconds
1,2,5,10,15,20,30,60 minutes (15 variations)
Recording Capacity 8,000 Readings x 2 Channels
Measurement method Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full)
LCD display Measurements (Ch1 only, Ch2 only, alternating display), Recording Status, Battery Life Warning, Amount of recorded Data, Unit of Measurement
Battery AA Alkaline Battery (LR6)
Battery Life Approximately 1 year **
Data Backup Activated when battery power is low or when switch is off
Interface USB Communication Cable (option: RS-232C)
Communication Speed Downloading 1 unit of full data - about 8 seconds
Dimensions H55mm x W78mm x D18mm
Weight About 62g
Standard Sensor TR-0106 x 2: (TEP resin sensor)
Software: For software description and specifications,
see TR7 Series Datasheet

 

TR-72U  
Measurement Channels 2: Temperature & Humidity
Internal Temperature Sensor
(Thermistor)
-10 to 60°C
External Temperature Sensor
(Thermistor)
-0 to 50°C
Optional Temperature Sensor Range -40 to 110°C
Humidity Sensor
(Macromolecular Humidity Sensor)
10 to 95%RH
Barometric Pressure Sensor
 
Temperature Accuracy (Standard Sensors) Average ±0.3°C (-20 to 80°C); Average ±0.5°C (-40 to -20°C / 80 to 110°C)
Humidity Accuracy ±5%RH (at 25°C 50%RH)
Barometric Pressure Accuracy N/A
Measurement Resolution Display 0.1°C / 1%RH
Recording Interval 1,2,5,10,15,20,30 seconds
1,2,5,10,15,20,30,60 minutes (15 variations)
Recording Capacity 8,000 Readings x 2 Channels
Measurement method Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full)
LCD display Measurements (Ch1 only, Ch2 only, alternating display), Recording Status, Battery Life Warning, Amount of recorded Data, Unit of Measurement
Battery AA Alkaline Battery (LR6)
Battery Life Approximately 1 year **
Data Backup Activated when battery power is low or when switch is off
Interface USB Communication Cable (option: RS-232C)
Communication Speed Downloading 1 unit of full data - about 8 seconds
Dimensions H55mm x W78mm x D18mm
Weight About 62g
Standard Sensor TR-3100 x 1: (Temp. humidity sensor)
Software: For software description and specifications,
see TR7 Series Datasheet

 

TR-73U  
Measurement Channels 3: Temperature, Humidity & Barometric Pressure
Internal Temperature Sensor
(Thermistor)
-10 to 60°C
External Temperature Sensor
(Thermistor)
-0 to 50°C
Optional Temperature Sensor Range -40 to 110°C
Humidity Sensor
(Macromolecular Humidity Sensor)
10 to 95%RH
Barometric Pressure Sensor
750 to 1100hPa
Temperature Accuracy (Standard Sensors) Average ±0.3°C (-20 to 80°C); Average ±0.5°C (-40 to -20°C / 80 to 110°C)
Humidity Accuracy  
Barometric Pressure Accuracy ±1.5hPa
Measurement Resolution Display 0.1°C / 1%RH / 0.1hPa
Recording Interval 1,2,5,10,15,20,30 seconds
1,2,5,10,15,20,30,60 minutes (15 variations)
Recording Capacity 8,000 Readings x 3 Channels
Measurement method Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full)
LCD display Measurements (Ch1 only, Ch2 only, Ch3 only, alternating display), Recording Status, Battery Life Warning, Amount of recorded Data, Unit of Measurement
Battery AA Alkaline Battery (LR6)
Battery Life Approximately 10 Months *
Data Backup Activated when battery power is low or when switch is off
Interface USB Communication Cable
Communication Speed Downloading 1 unit of full data - about 12 seconds
Dimensions H55mm x W78mm x D18mm
Weight About 62g
Standard Sensor TR-3100 x 1: (Temp. humidity sensor)
Software: For software description and specifications,
see TR7 Series Datasheet

* There are two types of temperature sensor for TR-71U depending on measurement range
** Battery Life differs depending on measurement environment and battery performance


TR-07K2 ABS Bracket


RTR-57U Data Collector for remote downloading (requires TR-6C10 cable)

Cal Cert

NIST-Traceable Calibration

Model: CAL-2PT

  • 2-Point calibration
  • Traceable certificate
2-point temperature calibration performed in ThermoWorks' NIST-Traceable calibration lab. Includes calibration report and actual test data.


Cal Cert

NIST-Traceable RH Calibration

Model: CAL-RH2PT

  • 2-Points: 30%, 60%
  • Lab calibration using certified RH sources
2-point humidity calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes calibration report and actual test data.

To Order:

TR-71U Dual Channel Temperature Recorder with Probes (TR-0106) & Software
TR-72U Temperature/Humidity Recorder with Probe (TR-3100) & Software
TR-73U Temperature/Humidity/Barometric Pressure Recorder with Probe (TR-3100) & Software
RTR-57U Handheld Data Collector w/software & Cable (USB)
TR-6C10 Communication download cable (for use with RTR-5U)
TR-07K2 Wall mount bracket (ABS), TR-7 Series
CAL-2PT NIST-Traceable Calibration Certificate, 2 points, (32°F & 122°F)
CAL-RH2PT NIST-Traceable RH Calibration Certificate, 2 points (30% & 60%),
includes single temperature at ambient

 

Optional Probes      
Model/Description Temp Range Price  
Temperature (TR-71U / TR-72U / TR-73U)      
TR-0106 T&D Replacement Teflon Sheath Temperature Probe
-40 to 230°F
(-40 to 110°C)
TR-1220 T&D Optional Stainless Steel Temperature Immersion Probe
-76 to 311°F
(-60 to 155°C)
TR-0506 T&D Optional Stainless Steel Penetration Probe, 11.5"L
-40 to 230°F
(-40 to 110°C)
TR-0706 T&D Optional Stainless Steel Penetration Probe, 2"L
-40 to 230°F
(-40 to 110°C)
TR-1C30 T&D Extension Cable for Temperature Probes only. 10'L
 
TR-5C10 T&D Extension Cable for Temperature Probes or TR-3100 Temp/Humidity Probe.3'L
 
Temperature/Humidity (TR-72U / TR73U)      
TR-3100 T&D Replacement Temperature/Humidity Probe
32 to 122°F
(0 to 50°C)
10% to 95%RH
TR-3110 T&D Optional Temperature/Humidity Probe w/40" Cable
32 to 122°F
(0 to 50°C)
10% to 95%RH

Our Company