Close Focus Infrared Thermometer

Model #CF-IR

0.7 inch (18mm) measurement distance
0.1 inch (2.5mm) spot size
Dual laser
Max temp and hold features
Easily switch from °C to °F
Clock and chronograph
Adjustable emissivity

List $199 Temporary Reduction

Bookmark and Share

Click and hover for detail. Click again for full zoom.

Measure temperature precisely to 0.1" (2.5mm) with our new CF-IR Close Focus Infrared Thermometer. Great for electronic components, laboratory measurements, and research. Most IR units require a minimum of 0.75" diameter spot area. Now you can measure tiny areas with precision.

The CF-IR multi-line display includes a real-time clock and measurement of ambient temperature for convenience. Other features include Min/Max, Hold, adjustable emissivity, and built-in stop watch. Measure temperatures from -67°F to 428°F at 0.7" (18mm) distance.

You won't find a comparable close focusing IR unit for under $200. It works great for circuit boards, electrical components, precision heat testing, plastic molding, and laboratory use.

ThermoWorks continues to bring temperature innovation direct to you. Order direct and save.

Range -67 to 428°F / -55 to 220°C
Accuracy* ±(2+0.05/deg)°C from -67 to 32°F (-55 to 0°C);
±4°F (2°C) or ±2% of the reading, whichever is greater above 32°F (0°C)
Resolution Thermometer: 0.5°F (0.2°C)
Stop Watch: 1 sec.
Distance/Target 0.7 inch (18mm), with a 0.1 inch (2.5mm) spot size
Emissivity 0.95 default; adjustable to 1 in 0.05 increments
Environmental Range** 32 to 122°F (0 to 50°C)
Features Auto real time clock and room temperature while power is off; °C/°F switchable; MIN/MAX/LOCK; stop watch
Battery AAA x 2, 15 hrs. continuous (auto power off after 15 seconds)
Dimensions 6.7" x 1.5" x 1.0" (170 x 38 x 25 mm)
Weight 4.4 oz (125g) including two AAA cells
Certificate Includes Certificate of Conformance

*IR accuracy can be affected by the emissivity setting, target spot size, and rapid changes in ambient temperature.

**EMC/RFI:Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.


Precision Focusing
Focused IR measurements
to a 0.1" spot size.


Multi-Function Display
Min, max, hold, real-time clock, stopwatch, ambient, and current measurement all conveniently displayed.

Cal Cert

NIST-Traceable IR Food Service Calibration

Model: CAL-IRFS

  • 3-Points: 32°F, 140°F, 212°F (0°C, 60°C, 100°C)
  • Lab calibration using certified Blackbody sources
3-point infrared food service calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes calibration report and actual test data.