T and D RTR-5 Series Wireless Water Resistant Data Loggers
Model #RTR-51/52/52Pt/53
Wireless Logging to 300 feet (100m)
Water/splash resistant
Single Channel (RTR-51: internal)
Single Channel (RTR-52: external)
Dual Channel (RTR-53: temp/humid)
Single Channel (RTR-52Pt: external RTD)
Stores 16,000 readings
LCD temperature display
Optional 2 year battery life
Download wirelessly to handheld, PC, or LAN
Optional network hub with built-in email server
 Click and hover to zoom. Click again to view larger image.
Looking for a wireless data logger to use in harsh environments? Look no further. Our new TandD loggers are IP67/IP64 rated for water resistance. They also include a display so you don't have to download the data to see what the current temperature is. You can configure, monitor, and download data from these loggers up to 300 feet away with our handy wireless handheld unit.
Choose the model RTR-52 and attach an external probe to extend the temperature range to 311°F. For even higher temperatures, select the model RTR-52Pt and connect any 3-wire RTD (Pt100) and achieve temperatures to 1100°F. With a 16,000 reading memory bank, you can record up to 666 days at an interval of one hour. You can program these loggers to record at virtually any interval from 1 second to 1 hour.
Using the RTR-57U Handheld unit, you can store up to 256,000 readings on up to 250 data recording sessions before download. The RTR-57U can configure start time, logging intervals, and programmed settings from all of your loggers. Data can be previewed graphically and can operate for up to 100 hours on 2 AAA batteries.
Want more? How about getting an email if your wireless loggers exceed your pre-set temperature or humidity limits?. Add on the RTR-5W Network Hub for downloading and monitoring in real-time. Configure up to 3,800 loggers in up to 60 groups and collect data right onto your network. Send warning emails to up to 5 different address and get your notification right to your PDA phone.
You won't find a more rugged wireless LCD display datalogger than our RTR series.
 |
RTR-51A
Water Resistant Wireless Logger
TR-51A
- Single channel internal
- Water resistant
- Wireless up to 100m (300 feet)
- LCD temperature display
|
Range: -40 to 176°F
(-40 to 80°C)
Accuracy: ±0.9°F (±0.5°C) |
|
|
 |
RTR-52
Water Resistant Wireless Logger with External Probe
Model: TR-52
- Single channel external
- Splash resistant
- Wireless up to 100m (300 feet)
- LCD temperature display
|
Range: -76 to 311°F
(-60 to 155°C)
Accuracy: ±0.5°F (±0.3°C) from 4 to 176°F (-20 to 80°C)
|
|
|
 |
RTR-52-Pt
Water Resistant Wireless
High Temperature Logger.
Accepts 3-Wire RTD Probes
Model: RTR-52-Pt
- Single channel external
- Splash resistant
- Wireless up to 100m (300 feet)
- Uses 3-wire RTD platinum probes
|
Range: -372.8 to 1112°F
(-199.9 to 600°C)
Accuracy:±0.54°F (±0.3°C)
from -327.8 to 176°F
(-199.9 to 80°C)
±0.9°F (±0.5°C)
from 176 to 842°F
(80 to 450°C)
|
|
|
 |
RTR-53
Water Resistant Wireless Temp & Humidity Logger
Model: RTR-53
- Dual channel external
- Wireless up to 100m (300 feet)
- LCD temperature display
- Splash resistant
|
Range: -32 to 131°F
(0 to 55°C)
10 to 95% RH
Accuracy: ±0.5°F (±0.3°C)
±5% RH (at 25°C and 50% RH)
|
|
|
|
 |
Wireless
Data Collector & Repeater
RTR-50
- Battery powered, daisy-chained built-in repeater
- Real-time monitoring & scheduled downloads
- Connectcs via USB to PC
- Send email alerts
Download datasheet |
USB based data collection with built-in daisy chain repeater for all RTR-5 Series loggers for expanded range. Download data on demand or on schedule with real-time monitoring with PC based utility software. Battery powered for convenience in repeating signal in difficult places. Built-in alarm notification via email or text messaging.
|
|
|
 |
Wireless
Network Hub
RTR-5W
- Download on schedule or manually
- Manages up to 64 loggers in up to 60 groups
- LAN connection
- Web-enabled monitoring
- Send email alerts
Download datasheet |
Collect data from all RTR-5 Series loggers on demand or on scheduled intervals and save directly to any network drive. Web enabled software allows for current reading monitoring from anywhere on the network as well as logger setup and configuration. Built-in email client sends alerts via email. Capable of recording from up to 64 loggers in up to 60 groups. Multiple units can be connected to same LAN.
|
|
|
 |
Wireless
Data Collector
RTR-57U
- Range up to 300' (100M)
- Stores up to 260K readings
- Manages up to 64 loggers in up to 60 groups
- Monitors real-time data
|
Collect data from all registered RTR-5 Series loggers directly to the RTR-57U Handheld for later downloading to PC. Eliminates need for removing loggers from installation. Stores up to 260,000 readings from up to 250 download sessions. Controls start/stop, logging interval, as well as other logging functions in the field. Graphical display shows trend data. Monitor current readings from any logger in real-time. Includes backlit display for poorly lit areas.
|
|
|
| RTR-51 |
|
| Measurement Channel |
1 Temperature Channel |
| Internal Temp Sensor |
-40 to 80°C |
| External Temp Sensor |
- |
| External Humidity Sensor |
- |
| Measurement Accuracy |
±0.5°C |
| Measurement Display Resolution |
0.1°C |
| Sensor |
Thermistor |
| Recording Interval |
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes (15 variations) |
| Recording Capacity |
16,000 Readings x 1 Channel |
| Measurement method |
Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full) |
| LCD display |
Current Readings, Recording Settings, Battery Life Warning, Over Measurement Range Warning, Unit of Measurement |
| Battery |
Lithium battery (LS14250(SAFT) x 1 or AC Adapter |
| Battery Life |
Approximately 6 months (depends on environment, interval and battery performance) |
| Wireless |
FCC Part 15 section 249 / IC RSS-210 up to 100m (varies with condiiotns) |
| Interface |
Wireless (RTR-57U) Optical Communication (RTR-57U, TR-50C) |
| Communication Speed |
Wireless- Approx 2,000 readings/minute Optical- Approx 6,000 readings/minute |
| Water Resistance Capacity * |
IP67 |
| Dimensions |
H62mm x W47mm x D19mm (excluding protusions / antenna length 20mm) D50mm with RTR-05B1 |
| Weight |
56g (Including battery) 109g with RTR-05B1 |
| Temperature Resistance of Unit |
-40 to 80°C |
| Standard Sensor |
Built-in |
| Software |
Compatible with Microsoft Windows Vista English
For software description and specifications,
see pg. 5 of RTR5 Series Datasheet |
| |
RTR-52 |
RTR-52Pt |
| Measurement Channel |
1 Temperature Channel |
1 Temperature Channel |
| Internal Temp Sensor |
- |
| External Temp Sensor |
-60 to 155°C |
-199.9 to 600°C |
| External Humidity Sensor |
- |
| Measurement Accuracy |
Average ±0.3°C (-20 to 80°C)
Average ±0.5°C
(-40 to -20°C / 80 to 110°C)
Average ±1.0°C
(-60 to -40°C / 110 to 155°C) |
±0.3°C (-199.9 to 80°C) ±0.5°C (80 to 450°C) ±1.0°C (450 to 600°C)
(at 0 to 50°C/Sensor accuracy is not included) |
| Measurement Display Resolution |
0.1°C |
| Sensor |
Thermistor |
Any 3-wire RTD |
| Recording Interval |
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes (15 variations) |
| Recording Capacity |
16,000 Readings x 1 Channel |
| Measurement method |
Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full) |
| LCD display |
Current Readings, Recording Settings, Battery Life Warning, Over Measurement Range Warning, Unit of Measurement |
| Battery |
Lithium battery (LS14250(SAFT) x 1 or AC Adapter |
| Battery Life |
Approximately 6 months (depends on environment, interval and battery performance) |
| Wireless |
FCC Part 15 section 249 / IC RSS-210 up to 100m (varies with condiiotns) |
| Interface |
Wireless (RTR-57U) Optical Communication (RTR-57U, TR-50C) |
| Communication Speed |
Wireless- Approx 2,000 readings/minute Optical- Approx 6,000 readings/minute |
| Water Resistance Capacity * |
IP64 ** |
| Dimensions |
H62mm x W47mm x D19mm (excluding protusions / antenna length 20mm) D50mm with RTR-05B1 |
| Weight |
56g (Including battery) 109g with RTR-05B1 |
| Temperature Resistance of Unit |
-40 to 80°C |
| Standard Sensor |
TR-5106 |
RTR-05P |
| Software |
Compatible with Microsoft Windows Vista English
For software description and specifications,
see pg. 5 of RTR5 Series Datasheet |
Compatible with Microsoft Windows Vista English
For software description and specifications,
see pg. 5 of RTR5 Series Datasheet |
| RTR-53 |
|
| Measurement Channel |
1 Temp and 1 Humidity Channel |
| Internal Temp Sensor |
- |
| External Temp Sensor |
0 to 55°C |
| External Humidity Sensor |
10 to 95%RH |
| Measurement Accuracy |
Average ±0.3°C (-20 to 80°C) ±5%RH (at 25°C and 50%RH) |
| Measurement Display Resolution |
0.1°C, 1%RH |
| Sensor |
- |
| Recording Interval |
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes (15 variations) |
| Recording Capacity |
8,000 Readings x 2 Channels |
| Measurement method |
Endless loop method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full) |
| LCD display |
Current Readings, Recording Settings, Battery Life Warning, Over Measurement Range Warning, Unit of Measurement |
| Battery |
Lithium battery (LS14250(SAFT) x 1 or AC Adapter |
| Battery Life |
Approximately 6 months (depends on environment, interval and battery performance) |
| Wireless |
FCC Part 15 section 249 / IC RSS-210 up to 100m (varies with condiiotns) |
| Interface |
Wireless (RTR-57U) Optical Communication (RTR-57U, TR-50C) |
| Communication Speed |
Wireless- Approx 2,000 readings/minute Optical- Approx 6,000 readings/minute |
| Water Resistance Capacity * |
IP64 ** |
| Dimensions |
H62mm x W47mm x D19mm (excluding protusions / antenna length 20mm) D50mm with RTR-05B1 |
| Weight |
56g (Including battery) 109g with RTR-05B1 |
| Temperature Resistance of Unit |
-40 to 80°C |
| Standard Sensor |
TR-3310 |
| Software |
Compatible with Microsoft Windows Vista English
For software description and specifications,
see pg. 5 of RTR5 Series Datasheet |
* Not for continued immersion
** The water resistance rating with the sensor or input cable connected is IP64
System Setup
USB or LAN
Select a sytem to meet your needs.
(click to enlarge)
Software
T&D Recorder for Windows (RTR-5)
- Software included in price of data collector
- Compatible with all RTR-5 Series logger, RTR-57U Handheld
- View up to 8 channels simultaneously on graphical display
- Graphical display with channel zoom, color editing, on/off channel display
- Data display with high, low, average, time and differential between markers
- File output compatible with .csv format
- Compatible with Windows 7 32/64 bit English, Vista 32 bit, XP SP2 or above
 |
ABS Bracket
Model: TR-05K3
- Convenient wall mounting bracket
- Operates in -40 to 176°F (-40 to 80°C) environment
- For use with all RTR-5 Series loggers
|
Monitor ambient conditions with optional wall bracket. Includes two screw holes for convenient attachment. For use with all RTR-5 Series loggers with standard battery. |
|
|
 |
Large Capacity Battery
Model: RTR-05B1
- Extends battery life to 2 years
- Includes high capacity Lithium battery
- Operates in -40 to 176°F (-40 to 80°C) environment
|
Extends the battery life of any RTR-5 Series logger from 6 months to 2 years. Kit includes high capacity Lithium battery, new o-ring seal, and new deeper rear housing to fit larger battery. Easy to install by removing two small screws on back housing. |
|
|
 |
AC Adapter
Model: RTR-05A1
- Connects any RTR-5 Series logger to AC power
- Includes Ni-MH battery for power loss (4 days)
- Operates in 32 to 140°F (0 to 60 °C) environment
|
Connects any RTR-5 Series logger to AC power for continuous use without worry of battery power loss. Includes NiMH backup battery for 4 days of power in event of AC power loss. Extends rear housing to fit components. Includes 110VAC power adapter, US plug. Easy to install in the field by removing two screws. |
|
|
 |
Low Temp Battery Set
Model: TR-11P2
- Lithium battery
- Insulation tube
- Maintenance kit
|
Low temperature battery kit for loggers. Includes battery, insulation tube and a maintenance kit for T&D loggers |
|
|
 |
NIST-Traceable Calibration
Model: CAL-2PT
- 2-Point calibration
- Traceable certificate
|
2-point temperature calibration performed in ThermoWorks' NIST-Traceable calibration lab. Includes calibration report and actual test data.
|
|
|
 |
NIST-Traceable RH Calibration
Model: CAL-RH2PT
- 2-Points: 30%, 60%
- Lab calibration using certified RH sources
|
2-point humidity calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes calibration report and actual test data.
|
|
|
| Optional Probes for RTR-52 / RTR-53: |
|
|
|
| Model/Description |
Temp Range |
Price |
|
|
TR-2C30 T&D Probe Extension Cable (RTR-52 only)  |
-76 to 311°F
(-60 to 155°C) |
|
|
|
TR-5106 T&D Replacement Teflon-Shielded General Purpose Immersion Probe  |
-76 to 311°F
(-60 to 155°C) |
|
|
|
TR-5220 T&D Optional Stainless Steel Sheath Immersion Probe  |
-76 to 311°F
(-60 to 155°C) |
|
|
|
TR-5420 T&D Optional Stainless Steel Sheath Penetration Probe  |
-76 to 311°F
(-60 to 155°C) |
|
|
|
TR-3310 T&D Optional Temp/Humidity Sensor (RTR-503)  |
32 to 131°F
(0 to 55°C)
10 to 95% RH |
|
|
| Optional Probes for RTR-52Pt: |
|
|
|
| Model/Description |
Accuracy |
Price |
|
|
TR-8100-4 T&D General Purpose Probe, -50 to 200°C
 |
±0.15°C @
0°C
(±0.27°F @
32°F) <Class A> |
|
|
|
TR-8120-8 T&D High Temperature Probe, -200 to 600°C  |
±0.15°C @
0°C
(±0.27°F @
32°F) <Class A> |
|
|
|
THS-160-125 T-Handle, Heavy-Duty Penetration Probe, -30 to 200°C  |
±0.15°C @
0°C
(±0.27°F @
32°F) <Class A> |
|
|
|
|