- Circle laser for better targeting
- High quality 12:1 optics
- IR range to 1022°F (550°C)
- Reads type K probes
- Adjustable emissivity
- Bright, backlit display
- Max/Min, C/F, Avg, High/Low Alarms
The IRK-2 infrared thermometer will be your favorite professional tool for broad range temperature measurements among industry and home use. The IRK-2 includes circle laser IR targeting, large LCD display, and extended temperature range.
The IRK-2 Infrared Thermometer is equipped with a circle laser indicator, which allows you to better approximate your target area without the guesswork of a single laser. The 8 laser dots show you the diameter of the area being measured. As you move closer or further from the target the laser circle will change diameter. This infrared thermometer has an adjustable emissivity feature, which allows you to measure a variety of surface types. For poorly lit areas, the infrared thermometer's backlit display can be toggled on (or off) for easy reading of surface temperatures.
The IRK-2 Infrared Thermometer includes a thermocouple socket for use with any type K thermocouple probe. A two line display shows infrared and thermocouple measurements simultaneously. And, with a 12:1 distance-to-spot ratio, the Industrial Infrared Thermometer allows you to measure small target areas from further away (1 inch spot at 12 inch distance). This keeps the lens cool when measuring hot surface temperatures.
The IRK-2 Infrared Thermometer's display features include Min/Max, Diff. Mode, Avg. Mode, Hi/Low alarms, and continuous scan mode with a large main temperature display, which reads in °F or °C. It's everything you need in a professional infrared thermometer.
Specifications | |
---|---|
Infrared Range | -58 to 1022°F (--50 to 550°C) |
Thermocouple Range | -83.2 to 2552°F (-64 to 1400°C) |
Temperature Resolution | 0.1° from -83.2 to 999.9°, 1° thereafter |
Infrared Accuracy* | Specifications listed are for ambient conditions between 68 and 78.8°F (20 and 26°C) 55 to 95°F (15 to 35°C): ±1.8°F (±1.0°C); 32 to 1022°F (0 to 550°C): 4°F (2°C) or ±2% of reading, whichever is greater -76 to 32°F (-60 to 0°C): ±4°F+0.09°F per degree below 32°F (2°C+0.05°C per degree below 0°C) |
Thermocouple Accuracy* | Dependent on Thermocouple. Meter adds 1.8°F (1°C) or 1% of reading, whichever is greater (when used in ambient conditions between 62.6 and 84.2°F (17 and 29°C)) to overall uncertainty |
Temperature Units | °C and °F switchable |
Probe Response Time | Probe dependent |
Infrared Response Time | 1 second |
Distance to Target | 12:1 (1” target diameter at a 12” distance) |
Emissivity | 0.95 default - adjustable 0.1 to 1 step 0.01 |
Spectral Range | 8 to 14 microns |
Environmental Range** | 32 to 122°F (0 to 50°C) |
Auto-Off | 60 seconds |
Battery | 2x AAA - included, 140 hours |
Dimensions | 4.7 H x 1.87 W x 6.76 D (119.2 H x 47.5 W x 171.8 D mm ) |
Weight | 9 oz. (256 g) including batteries (AAA x 2) |
Included Certificate | Certificate of Conformance |
*See 303-159 specifications here
**Accuracy can be affected by the emissivity setting, target spot size, and rapid changes in ambient temperature.
***EMC/RFI:Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.